Premier Plasma Tech HelpPremier Plasma Tech Help
← Drawing → first cut

Step 3 of 12 · Ch 1

3. Safety rules that never bend

Stop conditions, dry vs live testing, and the one-change rule.

⚠ Safety — Hazardous voltage

Never touch THC arc-voltage terminals while energized. Raw plasma arc voltage can cause severe injury or death. Only a qualified person should connect arc-voltage wiring.

⚠ Safety — Never bypass safety circuits

Never bypass the emergency stop, limit circuit, charge pump, enclosure interlock, or protective earth to keep production running.

⚠ Caution — One change at a time

Record the starting condition, make one controlled change, and test again. Restore the original setting if the change did not help.

⚠ Caution — Dry test first

Use a dry test whenever a live arc is not required — plasma power off or torch-firing output safely disabled.

⚠ Safety — Unexpected torch fire

Press the physical emergency stop, isolate plasma input power, and do not continue until the output path is proven safe.

  1. 1. Premier troubleshooting method

    Make safe → reproduce → identify subsystem → one test → record → change one item.

  2. 2. Check order (keeps you and the machine safe)

    1 Cold mechanical (power off) → 2 Dry motion (power on, torch OFF) → 3 Torch signal → 4 Live cut. Jumping ahead causes most support pain.

  3. 3. Stop immediately if

    Motion is uncontrolled, an axis hits a hard stop, smoke/odor appears, conductors are hot, or the torch fires unexpectedly.

    Warning: Unexpected fire: physical E-stop, isolate plasma input power, prove the output path before continuing.

Stuck? Text or call Tech 602-899-1115