Appendix D

Quick fault index

Customer statement → first safe check. Routing backbone from Appendix D.

⚠ Caution — One change at a time

Record the starting condition, make one controlled change, and test again. Restore the original setting if the change did not help.

⚠ Caution — Dry test first

Use a dry test whenever a live arc is not required — plasma power off or torch-firing output safely disabled.

Symptom

You are not sure which category matches the failure.

Quick checks

  • ☐Write the exact symptom in one sentence
  • ☐Note when it last worked and what changed
  • ☐Note whether it fails on jog, dry run, torch signal, or live cut

Fix

Route by statement

Match the statement, then open the guided flow or article. Machine-specific wiring overrides generics.

  • Nothing moves → Motion: Reset/status, UC100 LEDs, E-stop/limit, control power
  • One axis dead → Motion: drive, connector, cable, binding, profile
  • Wrong distance → Motion: repeated measured move; profile vs mechanics
  • Gantry crooked → Motion: stop; both drive sides + slave
  • UC100 not found / Sync Error → Software/PC (+ Noise if at arc start)
  • Torch does not fire / pilot only → Won't cut
  • Torch dives / climbs / dashes → Torch height (THC)
  • Heavy slag / bevel / incomplete → Cut quality
  • Parts wrong size / holes last → Shape/accuracy or CAD/CAM
  • Random limit/disconnect at firing → Grounding/noise

Still stuck?

Text a photo — fastest path to a human who knows these tables.

We're in Glendale — same people who build the tables. Text beats voicemail.