Grounding and electrical noise

Random limits, UC100 drops, THC noise — especially at arc start.

⚠ Safety — Never bypass safety circuits

Never bypass the emergency stop, limit circuit, charge pump, enclosure interlock, or protective earth to keep production running.

⚠ Safety — Hazardous voltage

Never touch THC arc-voltage terminals while energized. Raw plasma arc voltage can cause severe injury or death. Only a qualified person should connect arc-voltage wiring.

⚠ Caution — One change at a time

Record the starting condition, make one controlled change, and test again. Restore the original setting if the change did not help.

Symptom

Limits trip, USB drops, or THC voltage goes crazy when the arc starts.

Quick checks

  • ☐Same program dry with plasma OFF — does fault disappear?
  • ☐Work lead short path to clean metal
  • ☐USB and signal cables separated from torch/work leads

Fix

Noise-control checklist

  • Never remove protective earth to 'test' noise
  • Optically isolated breakout between UC100 and machine
  • Cross power/signal at ~90° if they must meet
  • Proma Step/Dir shield ground at CNC side only (per Proma manual)
  • Prevent Windows USB selective suspend
  • Don't coil torch lead with signal cables

Prove it

Dry G-code → torch-signal without motion → short live straight cut while recording the exact failure moment. Ignition-only failures → work lead, separation, shielding, isolation before motor tuning.

Still stuck?

Text a photo — fastest path to a human who knows these tables.

We're in Glendale — same people who build the tables. Text beats voicemail.

Stuck? Text or call Tech 602-899-1115